This listing is for a job lot of used IME TDG82 current transformers and ABB RCBO (residual current circuit breaker with overcurrent protection) breakers. The items are sold as a lot and are shown in the photos. All items were removed from a working environment during decommissioning. Please inspect the photographs carefully for visual condition, labels and connection details; quantities and exact ratings should be confirmed from the unit labels prior to installation.
What you get
- 2 x IME TDG82 current transformer (split-core style) — please refer to photographs and label for exact sensitivity / primary window diameter / part code
- 6 x ABB RCBO breakers (2‑pole shown) — please refer to photographs and label for exact current rating, trip curve and part code
Features
- IME TDG82 current transformers: split‑core construction for clamp‑on installation without disconnecting conductors; compact housing with mounting provisions; fitted secondary connection cable and terminal block for easy wiring.
- ABB RCBO breakers: combined residual current device (RCD) and miniature circuit breaker (MCB) functionality — provides both earth‑leakage protection and overcurrent/short‑circuit protection in a single module; DIN‑rail mounting form factor; integral toggle for manual operation and reset.
- Designed for use in electrical distribution and protection applications: monitoring, selective earth‑fault protection and branch circuit protection.
- Suitable for retrofit or replacement in compatible panels — check dimensions and terminal arrangements against your installation.
Specifications
Note: Exact specifications vary by unit and must be confirmed from the label on each device. The lists below describe typical/specification fields you should verify from the photographs or the item labels.
- IME TDG82 (typical fields to verify on unit):
- Model: TDG82 (as labelled)
- Type: Split‑core current transformer / residual current sensor
- Primary window diameter: [refer to label / measure opening]
- Sensitivity / nominal residual current (where marked): e.g. IΔn = [value] (check label)
- Secondary output / ratio: [check label – e.g. mA or A output depending on model]
- Connection: integral cable / terminal block (as shown)
- Mounting: base feet / clip (as shown)
- ABB RCBO breakers (typical fields to verify on unit):
- Manufacturer: ABB
- Type: RCBO (residual current operated circuit‑breaker with overcurrent protection)
- Poles: 2‑pole (as pictured)
- Rated current: [check unit label — e.g. 6A, 10A, 16A, 20A, 32A etc]
- Residual current (earth leakage) trip sensitivity: [check label — commonly 30 mA or 100 mA etc]
- Tripping characteristic (B, C, D etc): [check label for curve type]
- Mounting: DIN‑rail
- Connection: screw terminals (as pictured)
History
The devices were removed during an IT/electrical decommissioning project. They have been lightly used in a working environment and are being offered as a job lot. No further testing or calibration certificates are included unless stated elsewhere in the listing — please check all photos and labels for confirmation of ratings and condition.
Notes & Recommendations
- Quantities, ratings and full part codes must be confirmed from the photographs and the labels on the individual units prior to purchase; this template intentionally leaves [QTY] and specific rating fields for accurate completion.
- These are electrical protection and sensing devices — they should be installed and tested by a qualified electrician or engineer in accordance with local regulations and standards.
- No additional items are included beyond those shown and described above. All items are sold as seen.
If you need any particular label photographed or additional close‑up images of serial/part numbers on specific items, please request them before purchase.